Evaluation of artificial inteligence for predicting total water removal volume in maintenance hemodialysis patients (Evaluation of artificial inteligence (AI) for predicting total water removal volume in maintenance hemodialysis patients)

Evaluation of artificial inteligence for predicting total water removal volume in maintenance hemodialysis patients (Evaluation of artificial inteligence for predicting total water removal volume in maintenance hemodialysis patients)

Tanaka Tetsuhiro

Tohoku University Graduate School of Medicine

1-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574

+81-22-717-7163

tetsuhiro.tanaka.d3@tohoku.ac.jp

Ishibashi Tadashi

Hiroshima University Hospital

1-2-3, Kasumi, Minami-ku, Hiroshima, Hiroshima 734-8551

+81-82-257-5555

tishiba@hiroshima-u.ac.jp

Recruiting

Oct. 09, 2024

150

Observational

randomized controlled trial

open(masking not used)

uncontrolled control

single assignment

other

(1) Patients with chronic renal failure undergoing maintenance hemodialysis by a dialysis specialist as an outpatient 3 days a week
(2) Patients with a doctor-prescribed dialysis time of 4 to 5 hours
(3) Patients aged 20 years or older
(4) Patients who have given written consent to participate in the study

(1) Pregnant or possibly pregnant patients
(2) Patients who have been on hemodialysis for less than one year
(3) Home dialysis patients
(4) Patients who used the test device to learn about it (only applies to patients at Bosho Nishi-Shinjuku Clinic and Keiai Hospital before 2022)
(5) Patients who have a high fluid removal volume (5,000mL or more) or a low fluid removal volume (1,000mL or less) on average once a week or more, and whose weight gain is greater than 5% of dry weight on the first day and greater than 7% of dry weight on the second day

20age old over
No limit

Both

Chronic renal faiture

The accucacy rate: The correct answer was determined if the difference between the total amount of water removed by the test device and the target amount of water removed prescribed by the specialist was 12% or less of the amount of water removed set by the doctor (however, the maximum was 300 mL). The percentage of times the test device gave a correct answer was defined as the accuracy rate.

Renascience Inc.
AMED
Not applicable
Ethics Committee of Tohoku University Graduate School of Medicine
2-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi, Miyagi

+81-22-728-4105

ec_med@rinri.hosp.tohoku.ac.jp
Approval

Oct. 02, 2024

No

none

History of Changes

No Publication date
2 Nov. 08, 2024 (this page) Changes
1 Oct. 09, 2024 Detail