Influence of mechanical ventilation settings on breath-by-breath exhaled propofol concentration during general anesthesia: a pharmacokinetic study

Is exhaled propofol concentration influenced by mechanical ventilation settings?

Masui Kenichi

Yokohama City University Hospital

3-9 Fukuura, Kanazawa-ku, Yokohama Cty, Kanagawa, Japan

+81-45-787-2918

masui.ken.kg@yokohama-cu.ac.jp

Tsuchiya Tomonori

Yokohama City University Hospital

3-9 Fukuura, Kanazawa-ku, Yokohama Cty, Kanagawa, Japan

+81-45-787-2918

yiu41707@yokohama-cu.ac.jp

Pending

Oct. 16, 2023

30

Interventional

single arm study

open(masking not used)

uncontrolled control

single assignment

other

1) 30 scheduled surgery patients aged 18 and over who are hospitalized at Yokohama City University
Hospital (10 aged 18-49, 10 aged 50-69, 10 aged 70 and over. 5 males and 5 females in each age group)
2) Patients who are expected to undergo general anesthesia for more than 3 hours
3) Supine position, general anesthesia patient under double lung ventilation
4) Patients undergoing invasive arterial pressure catheter insertion
5) Patients who have given their written consent to participate in this study

1) Patients contraindicated for administration of propofol
2) Patients whose ASA classification, which is the general condition classification of the American Society of Anesthesiologists, is class 4 or higher
3) Surgery with head low or high at 25 degrees or more
4) Patients with interstitial pneumonia, COPD, pulmonary edema, severe cardiac dysfunction, severe liver
dysfunction
5) Pregnant women (lactating women)

18age old over
No limit

Both

Elective surgical procedure

1. Selection of anesthesia method (total intravenous anesthesia with propofol)
2. Mechanical ventilator settings during surgery

Anesthesia, Intravenous

E04.249

E03.155.308

Prediction Error (PEex) calculated using estimated end tidal expiratory propofol concentration and measured plasma propofol. PEex is defined as (measured plasma propofol concentration - end tidal propofol concentration)/end tidal propofol concentration or measured plasma propofol concentration/end tidal propofol concentration.

The PEex derivatives, pharmacokinetic indices median prediction error (MDPE) and median absolute prediction error (MDAPE), are used to assess the performance of end tidal propofol concentration as a predicted value of plasma propofol concentration. If respiratory conditions influence prediction error, prediction formula will be developed to improve the predictive performance of plasma propofol concentrations using end tidal propofol concentration. The time course of PEex is illustrated.
Prediction error of measured plasma propofol concentration vs predicted plasma propofol concentration is calculated as (measured plasma propofol concentration-predicted plasma propofol concentration)/predicted plasma propofol concentration, or as measured plasma propofol concentration/predicted plasma propofol
concentration. MDPE and MDAPE are also calculated using predicted plasma concentartion determined using the Marsh model. The time course of the prediction error is dipicted.
The end tidal propofol concentration and predicted plasma propofol concentration as predictive values of measured plasma propofol vconcentration are compared.

Yokohama City University Ethics Committee
3-9 Fukuura, Kanazawa-ku, Yokohama Cty, Kanagawa, Japan, Kanagawa

+81-45-787-2800

rinri@yokohama-cu.ac.jp
Approval

July. 14, 2023

Yes

The principal investigator or sub-investigator will fill in the necessary information on the case registration form and register it on the computer at the registration center. At this time, a research subject identification code is assigned at the conducting medical institution, but this research subject identification code consists of numbers and symbols that are unrelated to information that can identify a specific individual, such as initials or medical record ID. When creating documents related to this research, such as case registration forms and case report forms, research subject identification codes will be used to prevent individuals from being identified. The research director will use the processed information to create a correspondence table containing information such as the research subject's name and medical record ID so that the research subject can be identified if necessary, and leak it to the outside. Storage management shall be carried out strictly to ensure that no accident occurs. Data provided to joint research institutions, such as research subject case registration forms, case report forms, test data, and samples, must be provided with a research subject identification code or registration number. Data that has been processed so that individuals cannot be identified (limited to data that has been processed or managed so that it cannot be immediately determined which research subject's sample or information belongs to). When providing data to Shoreline Science Research, Inc., it is done by mailing an electromagnetic recording medium such as a USB memory with a password set. Additionally, equipment containing research data that does not include personal information will be transported by vehicle. Blood samples sent to the National Defense Medical College Hospital will be labeled using a research subject identification code and sent within three months of collection at a temperature below -30 degrees by a specialized vendor.